Electrical Wire Size Chart: 1, 1.5, 2.5, 4 and 6 sq mm Explained

Quick answer

Typical wire sizes in Indian homes: 1 to 1.5 sq mm for lights and fans, 2.5 sq mm for socket points, 4 sq mm for a geyser or AC on its own circuit, and 6 sq mm for larger ACs (about 2 ton and above). Always confirm the final size with a licensed electrician.

Wire size Typical use Current rating in conduit*
1.5 sq mm Lights, fans 15 A
2.5 sq mm Socket points 19 A
4 sq mm Geyser, AC (dedicated circuit) 26 A
6 sq mm Larger AC 33 A

*Indicative manufacturer ratings; see the full chart below.

In this article
  1. What "sq mm" means
  2. The standard behind house wire
  3. Electrical wire size chart: typical uses
  4. Current ratings: what manufacturers publish
  5. Coil lengths and billing: coil vs metre
  6. Stocking tips for an electrical counter
  7. Frequently asked questions

"Bhaiya, AC ke liye kaun sa wire?" Every electrical counter hears this daily. Customers want a quick answer, but wire size is a safety matter, so the honest answer is a starting point plus "confirm with your electrician". This electrical wire size chart explains what the sq mm numbers mean, which sizes are typically used for which circuits in Indian homes, what current ratings manufacturers publish, and how to bill coils and cut lengths cleanly. It is meant to help dealers explain and stock wire. It does not replace a licensed electrician's design for a specific house.

What "sq mm" means

House wires in India are sold by the cross-sectional area of the copper conductor, in square millimetres (sq mm). This is the area of the copper, not the outer diameter of the wire with insulation. A bigger area carries more current with less heating and less voltage drop.

Older customers may still use strand terms such as "3/20" or "7/22". Use sq mm on item names and invoices so everyone reads the same thing.

The common house-wiring sizes are 0.75, 1, 1.5, 2.5, 4 and 6 sq mm, with larger sizes (10, 16 sq mm and above) used for main incoming lines and heavier loads.

The standard behind house wire

Single-core PVC-insulated house wires are generally made to IS 694, which covers PVC-insulated cables for voltages up to and including 1100 V, with copper or aluminium conductors. The standard includes rigid and flexible conductor classes and categories such as FR (flame retardant) and FR-LSH (flame retardant, low smoke and halogen). Many brands also sell variants with their own trade names, such as HRFR (heat-resistant FR) or ZHFR. Read the packaging to see exactly what the product claims and which standard it is certified to.

At the counter, check that the coil carries the ISI mark and the IS 694 marking. That protects you and the customer.

Electrical wire size chart: typical uses

The table below combines typical household uses that wire manufacturers and electrical retailers publish in their guides. These are general, indicative figures. The right size for a circuit depends on the actual load, the length of the run, how many wires share a conduit and the ambient temperature. Always tell customers that the electrician decides.

Size (sq mm) Typical household use (indicative)
0.75 Light-duty flexible connections, low-load points
1.0 Lighting and fan points
1.5 Lighting and fan circuits; small appliance points such as a refrigerator
2.5 General socket (power) points; small appliances such as microwave, iron, washing machine; some smaller ACs
4.0 Geyser on a dedicated circuit; AC on a dedicated circuit
6.0 Larger ACs (around 2 ton and above, per some guides); sub-main lines
10 and above Main incoming line to the distribution board, as the electrician specifies

Which wire for AC?

Published guides disagree a little here, which shows why the electrician's call matters. One cable maker suggests 2.5 sq mm for smaller ACs up to about 1.5 ton and 4 sq mm for larger units on a dedicated circuit. Another retailer's guide suggests 2.5–4 sq mm for ACs up to 1.5 ton and 4–6 sq mm for 2 ton and above. Run length matters too. A long run from the meter board to a top-floor bedroom may need the next size up to limit voltage drop. Every AC should be on its own circuit with its own MCB, as the electrician designs it. The MCB rating must never be higher than what the wire can safely carry; a breaker larger than the wire lets the wire overheat before it trips. Never use socket wire for an AC or geyser just because it is already in the house.

Current ratings: what manufacturers publish

Manufacturers print current-carrying capacity tables in their catalogues. As an example, one Indian cable maker lists these ratings for its single-core FR PVC copper flexible wires (two single-core cables, single phase):

Size (sq mm) In conduit / trunking (A) Clipped direct / on tray (A)
0.75 8 9
1.0 11 12
1.5 15 16
2.5 19 23
4.0 26 30
6.0 33 38

Note how the rating drops when the wire is inside conduit. Heat cannot escape as easily. Ratings also fall with higher ambient temperature and when several circuits share one pipe. Figures differ between brands and product lines, so use the catalogue of the wire you sell, never a table from another brand.

Coil lengths and billing: coil vs metre

House wire is most commonly packed in 90-metre coils, and most brands' standard house-wire packs are 90 m. Some products and sizes come in other lengths, so check the label before quoting "per coil".

Electrical shops sell wire in two ways:

  1. Full coils, priced per coil
  2. Cut lengths, priced per metre, for repair work and small jobs

Worked example: metre billing from a coil

Illustrative prices only, not market rates.

Many shops charge a slightly higher per-metre rate for cut lengths than the coil rate, because they carry the leftover risk. That is your pricing choice. Just keep the per-metre rate on your price list so every staff member charges the same. A shared price list avoids counter-by-counter differences.

Worked example: a house-wiring order

Item Qty Example rate per coil Amount
1.5 sq mm FR wire, 90 m 3 coils ₹1,600 ₹4,800
2.5 sq mm FR wire, 90 m 2 coils ₹2,500 ₹5,000
4.0 sq mm FR wire, 90 m 1 coil ₹4,000 ₹4,000
Taxable value ₹13,800
CGST 9% ₹1,242
SGST 9% ₹1,242
Total ₹16,284

Total wire supplied: 6 coils × 90 m = 540 m. Wire and cable (HSN 8544) is at 18% GST, and so are switches, sockets and MCBs (HSN 8536). See the GST rates page for related items. GST rates and rules change, so check the latest CBIC notification or ask your CA before filing.

In billing software, set the metre as the base unit and the coil (90 m) as a larger unit. Then a full-coil sale and a 35 m cut both reduce the same stock correctly, and you can see that you hold "4 coils + 55 m". Multi-unit billing in MaterialBill is built for this kind of conversion; set up and test the metre and coil units before you go live. Keep stock separate by size, colour and product line (FR, FRLS and so on), because a customer who wants red 2.5 sq mm will not accept black.

Stocking tips for an electrical counter

Frequently asked questions

Which wire size is used for house lighting?

Lighting and fan points are commonly wired in 1 or 1.5 sq mm copper wire, according to manufacturers' guides. The electrician decides based on the circuit's load and length.

Which wire is used for AC?

Guides commonly suggest 2.5 sq mm for smaller ACs (about 1.5 ton and below) and 4 sq mm or more for larger units, on a dedicated circuit. Long runs may need a bigger size. Always follow the electrician and the AC maker's instructions.

What is the length of a wire coil?

Most house-wire coils sold in India are 90 m, but some products come in other lengths. Check the length printed on the packaging.

Is 2.5 sq mm enough for a geyser?

Several guides recommend 4 sq mm on a dedicated circuit for a geyser. The right size depends on the geyser's rating and the wiring run, so the electrician should confirm.

Should I bill wire per coil or per metre?

Both are acceptable. Bill full coils per coil and cut lengths per metre, and keep a metre-based stock so the balance stays accurate after every cut.

Clear sizes, honest advice and accurate coil-and-metre stock are what keep electricians coming back. If you want size-wise wire stock with multi-unit billing, you can start free with MaterialBill's wire and cable shop billing software.

Related articles

TMT Bar Weight Chart TMT Bar Grades Fe415, Fe500, Fe500D and Fe550D OPC vs PPC Cement (and PSC) Cement Shelf Life and Storage Cement Sand Aggregate Calculation for 1 Cubic Metre of Concrete How Many Bricks in a Wall All blog posts

Start Free Today

Set up in two minutes. No card required. Leave whenever you like — your data always stays yours.