Home › Blog › Product knowledge and calculators › PVC vs CPVC vs uPVC Pipes (and GI)

PVC vs CPVC vs uPVC Pipes (and GI): Uses, Sizes and What to Stock

Quick answer

Use uPVC for cold water, CPVC for hot and cold water (geyser and solar lines), SWR pipes for drainage, and GI for mains and fire lines.

Pipe Standard Use
uPVC pressure IS 4985 Cold water supply
uPVC SWR IS 13592 Drainage, soil, rainwater
CPVC IS 15778 Hot and cold water
GI IS 1239 Water mains, fire-fighting
In this article
  1. PVC vs CPVC vs uPVC pipes at a glance, plus GI
  2. uPVC pipes: pressure lines and SWR drainage
  3. CPVC pipes: hot and cold water
  4. GI pipes: where they still sell
  5. Pipe size chart: inch vs mm
  6. What to stock: a practical starting list
  7. Billing pipes by length and piece
  8. Frequently asked questions

A plumber asks for "¾-inch CPVC", a farmer wants "4-inch, 6 kg pipe", and a builder needs "110 SWR, Type B". Each is a different product family, standard and sizing system. Knowing PVC vs CPVC vs uPVC pipes, and where GI still fits, helps you stock the right range and never sell a cold-water pipe for a geyser line. This brand-neutral guide covers the main types of plumbing pipes in Indian shops, how they are sized and what to stock. The plumber and the project specification decide the final choice.

PVC vs CPVC vs uPVC pipes at a glance, plus GI

Pipe type What it is Typical uses Common Indian standard
uPVC pressure pipe Unplasticised PVC, rigid Cold water supply, potable water lines, irrigation IS 4985 (water supply)
uPVC SWR pipe Unplasticised PVC, thin to medium wall Soil, waste, vent and rainwater lines inside buildings IS 13592
CPVC pipe Chlorinated PVC, handles higher temperature Hot and cold water supply in homes, solar and electric heater lines IS 15778 (½" to 2" sizes)
GI pipe Galvanised steel tube Water mains, older plumbing, fire-fighting and other uses IS 1239 (Part 1)

"PVC pipe" at the counter usually means one of the uPVC families. Always ask: pressure or drainage, hot or cold?

uPVC pipes: pressure lines and SWR drainage

uPVC pressure pipes (cold water and agriculture)

IS 4985 covers unplasticised PVC pipes for potable water supply, including agricultural use. Pipes are graded by working pressure classes, rated at 27 °C. Commonly listed classes run from 0.25 MPa to 1.25 MPa, which the trade calls roughly 2.5 to 12.5 kgf/cm² (1 MPa is about 10.2 kgf/cm²). Check the brand's catalogue for the classes it makes in each size. This is where the trade terms "4 kg pipe", "6 kg pipe" and "10 kg pipe" come from: they are the pressure class in kgf/cm², not the weight of the pipe.

Sizes under IS 4985 follow outside diameter in mm, for example 20, 25, 32, 40, 50, 63, 75, 90, 110 mm and upward. One major manufacturer lists its IS 4985 range from 20 to 450 mm. Higher pressure classes have thicker walls at the same OD.

Some brands also sell uPVC plumbing pipes in inch sizes made to ASTM Schedule 40 / Schedule 80, aimed at cold-water lines in buildings. This is a different sizing system from IS 4985, and the fittings are not interchangeable.

uPVC is meant for cold water, not geyser or solar hot-water lines.

uPVC SWR pipes (drainage inside buildings)

SWR means Soil, Waste and Rainwater. IS 13592 covers uPVC pipes for soil and waste discharge inside buildings, including ventilation and rainwater. It sets out two types:

Nominal outside diameters under the standard run from 40 mm to 160 mm, and lengths of 2, 3, 4 or 6 m. Brands also sell short single- or double-socket pieces, and some offer ring-fit (rubber-seal) joints.

Do not sell Type A for a toilet soil line to save money.

CPVC pipes: hot and cold water

CPVC (chlorinated PVC) handles hot water, which is why it is widely used for in-house hot and cold supply. IS 15778 covers CPVC pipes in the ½-inch to 2-inch range, in two wall classes, SDR 11 and SDR 13.5 (SDR is the ratio of outside diameter to wall thickness, so a lower SDR means a thicker wall). One manufacturer rates its CPVC pipes for water up to 82 °C. Larger sizes (2½ inch and up) are often made to an ASTM standard in Schedule 40 or 80.

CPVC sizes are commonly sold in inches: ½", ¾", 1", 1¼", 1½" and 2". Standard lengths vary by brand. One manufacturer, for example, sells 3 m and 5 m lengths. The pressure and temperature ratings for each SDR are on the brand's catalogue, so follow it, and follow the plumber, for geyser and solar connections.

GI pipes: where they still sell

GI (galvanised iron, actually galvanised steel) tubes are made to IS 1239 (Part 1), in three classes: Light, Medium and Heavy. Under the standard, the class is embossed on the tube (L, M or H) along with the IS number and maker's name, and colour bands identify the class. The BIS product manual's licence scope covers nominal bores from 15 mm to 150 mm.

GI is still bought for water mains, rural water-supply schemes and fire-fighting systems where the specification calls for it. One state public health engineering department notes that medium-class GI is mostly used in its rural schemes.

GI pipe vs PVC: how to advise

Plastic pipes are lighter, easier to cut and join, and don't rust. GI needs threading but resists impact better, which is why it is still used in exposed runs. For fire-fighting and engineered systems, the consultant's drawing decides. Don't substitute.

Pipe size chart: inch vs mm

The table shows common counter trade equivalents, not exact conversions: GI uses nominal bore, IS 4985 PVC uses outside diameter, and CPVC uses its own inch-based series.

Trade size (inch) GI nominal bore (mm) GI outside diameter range per standard tables (mm)
½" 15 about 21.0–21.8
¾" 20 about 26.5–27.3
1" 25 about 33.3–34.2
1¼" 32 about 42.0–42.9
1½" 40 about 47.9–48.8
2" 50 about 59.7–60.8

For PVC and CPVC, read the catalogue of the brand you stock. A "1-inch" pipe in one system will not take a fitting from another system. Label racks with both the trade size and the system, for example "CPVC ¾" SDR 11" or "uPVC 32 mm 6 kg".

What to stock: a practical starting list

Your mix depends on your customers. A typical neighbourhood plumbing counter carries:

Fittings make up most of the item count, so set up your item master carefully. Our stock management guide and low-stock alerts help you keep fast-moving elbows in stock.

Billing pipes by length and piece

Pipes are sold by the length (each 3 m or 6 m piece), sometimes by the metre after cutting. Fittings go by piece or box.

Length calculation example: a plumber needs about 40 m of ¾" CPVC. In 3 m lengths, 40 ÷ 3 = 13.3, so 14 lengths. In 5 m lengths, 40 ÷ 5 = 8 lengths.

Invoice example (illustrative rates only, not market prices):

Item Qty Example rate Amount
CPVC pipe ¾", 3 m length 14 ₹250 ₹3,500
uPVC SWR 110 mm Type B, 3 m 6 ₹600 ₹3,600
CPVC elbow ¾" 20 ₹15 ₹300
Taxable value ₹7,400
GST 18% ₹1,332
Total ₹8,732

PVC pipes and fittings (HSN 3917) and GI/MS pipes (HSN 7306) are both at 18% GST. See our GST rates page for related items. GST rates and rules change, so check the latest CBIC notification or ask your CA before filing.

Setting "length" as the main unit with a metre equivalent lets you bill both full pipes and cut pieces. In MaterialBill, barcode billing helps at a busy counter where fittings look nearly identical.

Frequently asked questions

What is the difference between PVC, uPVC and CPVC pipes?

Rigid plumbing "PVC" pipes are usually uPVC (unplasticised PVC), used for cold water and drainage. CPVC is chlorinated PVC that handles hot water, which is why it is used for geyser and hot-water lines. Each has its own standards and fittings.

Can uPVC pipe be used for hot water?

uPVC is meant for cold water. For hot water lines, use CPVC rated for the temperature, as per the manufacturer's catalogue and the plumber's advice.

What does "6 kg pipe" mean?

It refers to the pressure class of a uPVC pressure pipe, about 6 kgf/cm² working pressure (0.6 MPa under IS 4985), not the pipe's weight.

Which SWR type is used for toilets?

Type B under IS 13592 is for soil and waste discharge. Type A is for ventilation and rainwater.

Is GI pipe better than PVC?

It depends on the use. GI resists impact better and is still specified for some mains and fire-fighting systems, while plastic suits most in-house plumbing. Follow the plumber or the project specification.

A well-organised pipe counter is mostly about knowing the systems apart and keeping fittings in stock. If you want size-wise stock, multi-unit billing and low-stock alerts, you can start free with MaterialBill's PVC pipe shop billing software.

Related articles

TMT Bar Weight Chart TMT Bar Grades Fe415, Fe500, Fe500D and Fe550D OPC vs PPC Cement (and PSC) Cement Shelf Life and Storage Cement Sand Aggregate Calculation for 1 Cubic Metre of Concrete How Many Bricks in a Wall All blog posts

Start Free Today

Set up in two minutes. No card required. Leave whenever you like — your data always stays yours.